Nihon Kohden · Patient monitoring

SVM-7100

SVM-7130 / SVM-7160

Spot-check vital signs monitor from Nihon Kohden with 8-inch colour screen for NIBP and SpO2, temperature optional. Spot and Continuous mode, MEWS and HL7 output. SVM-7130 and SVM-7160.

Screen
8-inch colour TFT LCD
Weight
2.1 kg
Battery life
6 hours (test conditions, see specifications)
Price
On quote
SVM-7100

The SVM-7100 series (SVM-7130 and SVM-7160) is a vital signs monitor from Nihon Kohden for spot-check measurements, with an 8-inch colour screen. The monitor measures NIBP and SpO2; temperature is optional. The SVM-7160 uses Nihon Kohden SpO2, the SVM-7130 Masimo SpO2.

In addition to Spot mode, a Continuous mode is available. The monitor offers a Modified Early Warning Score (MEWS), customisable shortcut keys and HL7 output to the hospital network.

Specifications

Type
Vital Signs Monitor / Spot Check Monitor for monitoring and alarming of NIBP (systolic, diastolic, MAP), pulse rate, SpO2 and temperature in adult, paediatric and neonatal patients in hospital environments. Two monitoring modes: Spot mode and Continuous mode.
Versions (SpO2 technology)
SVM-7160: Nihon Kohden SpO2 and NIBP. SVM-7130: Masimo SpO2 and NIBP. Temperature is an option on both.
Screen
8-inch colour TFT LCD; resolution 800 × 600 dots; visible area 162.0 × 121.5 mm.
Display
One waveform (SpO2 pulse wave); numeric: NIBP (SYS, DIA, MAP), SpO2, SpO2-PR and temperature. Sweep speed 6.25, 12.5, 25 or 50 mm/s. Shortcut keys at the bottom of the screen are customisable.
NIBP
Oscillometric (deflation and inflation mode). Measurement range adult/child: SYS 40–280 mmHg, DIA 10–235 mmHg, MAP 10–280 mmHg. Neonate: SYS 30–140 mmHg, DIA 10–110 mmHg, MAP 10–140 mmHg. Measurement modes: manual, STAT, periodic and SIM; 1 automatic re-measurement. Maximum cuff pressure error: ±3 mmHg (0–300 mmHg).
SpO2 and pulse rate
Declared range 70–100% SpO2. SVM-7160 (Nihon Kohden): accuracy (rms) ±2% SpO2 at 80–100% and ±3% SpO2 at 70–80%; pulse rate 30–300 beats/min, ±3% ±1 beat/min. SVM-7130 (Masimo): accuracy depends on the sensor; pulse rate 25–240 beats/min.
Temperature (option)
Optional with EXERGEN temporal thermometer (only available in Europe) or RADIANT ear thermometer. With the RADIANT thermometer: display range 34–42.2 °C.
Early warning score
Modified Early Warning Score (MEWS): determines the severity of the patient's condition based on, among other things, SpO2, NIBP, temperature and respiratory rate; can be set in advance.
Workflow
Illustrated on-screen tutorials for correct use, customisable shortcut keys and transfer of measured data to the electronic patient record (EPR) system via HL7 with one touch.
Review and storage
Spot mode: Spot Table and Alarm History. Continuous mode: Spot Table, Trend Table, Trend Graph and Alarm History. Maximum of 10,000 data entries per view; the trend graph covers the past 120 hours.
Alarms
Alarm levels: crisis, warning and advisory. Alarm silence 1, 2 or 3 minutes; alarm suspend 1, 2, 3 minutes or off; alarm delay adjustable 0–30 s. Delay to the central monitor ≤ 4 seconds.
Network and interfaces
HL7 output to the hospital network (Spot and Continuous mode). In Continuous mode, LS-NET connection to the Nihon Kohden monitor network (central monitor, other bedside monitors and server). Optional wireless LAN module QI-710P (IEEE 802.11a/b/g/n).
Dimensions (W × H × D)
232 × 246 × 135 mm (excluding protruding parts).
Weight
2.1 kg (monitor). Battery pack SB-710P: 325 g; optional recorder module WS-710P: 0.25 kg ± 0.1 kg.
Battery
Rechargeable lithium-ion battery SB-710P (1 piece), 7.2 V. Operating time 6 hours (new, fully charged battery at 25 °C, energy-saving mode on, no alarm, no options; SpO2 is measured and NIBP every 15 minutes). Charging time: 90% in 6 hours, fully in 8 hours.
Power
100–240 V AC (±10%), 50 or 60 Hz (±2%), 140 VA.
Environment
Operation: 5–40 °C, 15–85% RH (non-condensing), 700–1060 hPa. Transport and storage: –20 to +65 °C, 10–95% RH, 700–1060 hPa. Protection against falling water: IPX1 (not for the temperature option).
Recording (option)
Optional recorder module WS-710P: thermal array recording, recording width ≥ 46 mm, paper speed 12.5, 25 or 50 mm/s; manual, periodic and alarm recording.

Documents

Need the datasheet, instructions for use or CE declaration of SVM-7100? We send them on request.

Request documents →

IT and network

For your ICT department: what we know from the manufacturer's documentation. We agree the requirements for your hospital with your ICT.

Network and Wi-Fi
In Continuous mode an LS-NET connection to the Nihon Kohden monitor network (central monitor, other bedside monitors and server).
Optional wireless LAN module QI-710P (IEEE 802.11a/b/g/n).
Interfaces (HL7, PACS, ADT)
HL7 output to the hospital network (Spot and Continuous mode).
Transfer of measured data to an electronic patient record via HL7 with one touch.

A full IT checklist for your hospital ICT? Ask us.

Request the IT checklist →

About this system

One partner, from delivery to maintenance

We supply, install and maintain the device, and we supply the consumables. That gives you one point of contact for everything around your system.

Installation and instruction

On site, with your team.

Training

The content is stated in the quote.

Inspection and maintenance

We record the arrangements in your quote or service contract.

Remote support

Where your hospital allows VPN or TeamViewer, we can look in remotely.

Knowledge for this system

Capnografie en EtCO₂-bewaking: wat het meet en wanneer het helptWat capnografie en EtCO₂ meten, hoe u het capnogram leest en wat richtlijnen zeggen over capnografie bij beademing, reanimatie en sedatie, met…Read the article
Bispectrale index (BIS): de diepte van anesthesie metenWat de bispectrale index meet, hoe u de waarde leest, wat onderzoek zegt over bewustzijn tijdens narcose en hoe de BIS-meting past…Read the article
Anesthesiegasmeting en de MAC-waarde: wat de concentratie zegt over de narcoseHoe anesthesiegasmeting werkt, wat de MAC-waarde wel en niet zegt over de narcosediepte en wat de Multi Gas Unit van Nihon Kohden…Read the article

Other Nihon Kohden systems

Central station CNS-2101Central monitor as a panel PC with flat touchscreen, HL7 interface to the electronic patient record (EPR) system and alarm escalation; expandable with licences for 16, 24 or 32 beds.View Central station CNS-2101
Life Scope G3Wearable vital signs telemeter from Nihon Kohden for ECG, respiration and SpO₂ (GZ-130P); the GZ-140P also measures NIBP (iNIBP). Wireless LAN and LS-NET, 3.2-inch colour screen.View Life Scope G3
Vismo PVM-4000Bedside monitor series with six models (PVM-4731 to PVM-4763), with a choice of Nihon Kohden, Nellcor or Masimo SpO2 and optional esCCO.View Vismo PVM-4000
Not sure which system fits?One of our colleagues will help you choose, also if you have several departments.Contact us

Try first

Try SVM-7100 first?

One of our colleagues will schedule a demo at your department.