Nihon Kohden · Patient monitoring
SVM-7100
SVM-7130 / SVM-7160
Spot-check vital signs monitor from Nihon Kohden with 8-inch colour screen for NIBP and SpO2, temperature optional. Spot and Continuous mode, MEWS and HL7 output. SVM-7130 and SVM-7160.
- Screen
- 8-inch colour TFT LCD
- Weight
- 2.1 kg
- Battery life
- 6 hours (test conditions, see specifications)
- Price
- On quote

For owners of this device
Do you have this device?
Choose what you need. We fill in SVM-7100 for you.
The SVM-7100 series (SVM-7130 and SVM-7160) is a vital signs monitor from Nihon Kohden for spot-check measurements, with an 8-inch colour screen. The monitor measures NIBP and SpO2; temperature is optional. The SVM-7160 uses Nihon Kohden SpO2, the SVM-7130 Masimo SpO2.
In addition to Spot mode, a Continuous mode is available. The monitor offers a Modified Early Warning Score (MEWS), customisable shortcut keys and HL7 output to the hospital network.
Specifications
- Type
- Vital Signs Monitor / Spot Check Monitor for monitoring and alarming of NIBP (systolic, diastolic, MAP), pulse rate, SpO2 and temperature in adult, paediatric and neonatal patients in hospital environments. Two monitoring modes: Spot mode and Continuous mode.
- Versions (SpO2 technology)
- SVM-7160: Nihon Kohden SpO2 and NIBP. SVM-7130: Masimo SpO2 and NIBP. Temperature is an option on both.
- Screen
- 8-inch colour TFT LCD; resolution 800 × 600 dots; visible area 162.0 × 121.5 mm.
- Display
- One waveform (SpO2 pulse wave); numeric: NIBP (SYS, DIA, MAP), SpO2, SpO2-PR and temperature. Sweep speed 6.25, 12.5, 25 or 50 mm/s. Shortcut keys at the bottom of the screen are customisable.
- NIBP
- Oscillometric (deflation and inflation mode). Measurement range adult/child: SYS 40–280 mmHg, DIA 10–235 mmHg, MAP 10–280 mmHg. Neonate: SYS 30–140 mmHg, DIA 10–110 mmHg, MAP 10–140 mmHg. Measurement modes: manual, STAT, periodic and SIM; 1 automatic re-measurement. Maximum cuff pressure error: ±3 mmHg (0–300 mmHg).
- SpO2 and pulse rate
- Declared range 70–100% SpO2. SVM-7160 (Nihon Kohden): accuracy (rms) ±2% SpO2 at 80–100% and ±3% SpO2 at 70–80%; pulse rate 30–300 beats/min, ±3% ±1 beat/min. SVM-7130 (Masimo): accuracy depends on the sensor; pulse rate 25–240 beats/min.
- Temperature (option)
- Optional with EXERGEN temporal thermometer (only available in Europe) or RADIANT ear thermometer. With the RADIANT thermometer: display range 34–42.2 °C.
- Early warning score
- Modified Early Warning Score (MEWS): determines the severity of the patient's condition based on, among other things, SpO2, NIBP, temperature and respiratory rate; can be set in advance.
- Workflow
- Illustrated on-screen tutorials for correct use, customisable shortcut keys and transfer of measured data to the electronic patient record (EPR) system via HL7 with one touch.
- Review and storage
- Spot mode: Spot Table and Alarm History. Continuous mode: Spot Table, Trend Table, Trend Graph and Alarm History. Maximum of 10,000 data entries per view; the trend graph covers the past 120 hours.
- Alarms
- Alarm levels: crisis, warning and advisory. Alarm silence 1, 2 or 3 minutes; alarm suspend 1, 2, 3 minutes or off; alarm delay adjustable 0–30 s. Delay to the central monitor ≤ 4 seconds.
- Network and interfaces
- HL7 output to the hospital network (Spot and Continuous mode). In Continuous mode, LS-NET connection to the Nihon Kohden monitor network (central monitor, other bedside monitors and server). Optional wireless LAN module QI-710P (IEEE 802.11a/b/g/n).
- Dimensions (W × H × D)
- 232 × 246 × 135 mm (excluding protruding parts).
- Weight
- 2.1 kg (monitor). Battery pack SB-710P: 325 g; optional recorder module WS-710P: 0.25 kg ± 0.1 kg.
- Battery
- Rechargeable lithium-ion battery SB-710P (1 piece), 7.2 V. Operating time 6 hours (new, fully charged battery at 25 °C, energy-saving mode on, no alarm, no options; SpO2 is measured and NIBP every 15 minutes). Charging time: 90% in 6 hours, fully in 8 hours.
- Power
- 100–240 V AC (±10%), 50 or 60 Hz (±2%), 140 VA.
- Environment
- Operation: 5–40 °C, 15–85% RH (non-condensing), 700–1060 hPa. Transport and storage: –20 to +65 °C, 10–95% RH, 700–1060 hPa. Protection against falling water: IPX1 (not for the temperature option).
- Recording (option)
- Optional recorder module WS-710P: thermal array recording, recording width ≥ 46 mm, paper speed 12.5, 25 or 50 mm/s; manual, periodic and alarm recording.
Documents
Need the datasheet, instructions for use or CE declaration of SVM-7100? We send them on request.
Request documents →IT and network
For your ICT department: what we know from the manufacturer's documentation. We agree the requirements for your hospital with your ICT.
- Network and Wi-Fi
- In Continuous mode an LS-NET connection to the Nihon Kohden monitor network (central monitor, other bedside monitors and server).
Optional wireless LAN module QI-710P (IEEE 802.11a/b/g/n). - Interfaces (HL7, PACS, ADT)
- HL7 output to the hospital network (Spot and Continuous mode).
Transfer of measured data to an electronic patient record via HL7 with one touch.
A full IT checklist for your hospital ICT? Ask us.
Request the IT checklist →About this system
One partner, from delivery to maintenance
We supply, install and maintain the device, and we supply the consumables. That gives you one point of contact for everything around your system.
Installation and instruction
On site, with your team.
Training
The content is stated in the quote.
Inspection and maintenance
We record the arrangements in your quote or service contract.
Remote support
Where your hospital allows VPN or TeamViewer, we can look in remotely.
Knowledge for this system
Other Nihon Kohden systems
Try first
Try SVM-7100 first?
One of our colleagues will schedule a demo at your department.